SAFETY-KLEEN CORP -- BLASTER ABRASIVE, 550 -- 5350-00N044755
===================== Product Identification ===================== Product ID:BLASTER ABRASIVE, 550 MSDS Date:12/01/1989 FSC:5350 NIIN:00N044755 MSDS Number: BSCHY === Responsible Party === Company Name:SAFETY-KLEEN CORP Address:777 BIG TIMBER RD City:ELGIN State:IL ZIP:60123 Country:US Info Phone Num:708-697-8460; 312-942-5969 Emergency Phone Num:800-942-5969;800-424-9300(CHEMTREC) CAGE:30530 === Contractor Identification === Company Name:SAFETY-KLEEN CORP Address:1301 GERVAIS ST, SUITE 300 Box:City:COLUMBIA State:SC ZIP:29201 Country:US Phone:1-803-933-4200 CAGE:30530 ============= Composition/Information on Ingredients ============= Ingred Name:ZIRCONIUM (IV) SILICATE (1:1); (ZIRCONIUM (IV)) (ZIRCON) CAS:14940-68-2 RTECS #:ZH9000000 Fraction by Wt: 3% OSHA PEL:5 MG/M3; 10 STEL ACGIH TLV:5 MG/M3; 10 STEL Ingred Name:SILICA, CRYSTALLINE - QUARTZ; (CRYSTALLINE SILICA) CAS:14808-60-7 RTECS #:VV7330000 Fraction by Wt: 5% OSHA PEL:0.1 MG/M3 RDUST ACGIH TLV:0.1 MG/M3 RDUST ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO Health Hazards Acute and Chronic:ACUTE: SKIN:IRRITATION DUE TO MECHANICAL ABRASION. EYES:IRRITATION DUE TO MECHANICAL ABRASION. INHALATION:IRRITATION DUE TO MECHANICAL ABRASION. INGESTION:IRRITATION DUE TO MECHANICAL ABRASION. CHRONI C: INHALATION:IF BROKEN DOWN INTO RESPIRABLE PARTICLES, DUST MAY BE HARMFUL TO RESPIRATORY SYSTEM. (EFTS OF OVEREXP) Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ: IARC MONOGRAPHS, SUPPLEMENT. VOL 7, PG 341, 1987:GROUP 2A. NTP 6TH ANNUAL REPORT ON (SUPDAT) Effects of Overexposure:HLTH HAZ:LONG-TERM EXPOSURE MAY CAUSE COUGHING, WHEEZING, REDUCED PULMONARY FUNCTION AND SILICOSIS. MAY INCREASE SUSCEPTIBILITY TO TUBERCULOSIS, LIVER AND KIDNEY DAMAGE. SMOKING CAN INCREASE RISK OF I NJURY. Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PRE-EXISTING LUNG DYSFUNCTION MAY HAVE INCREASED SUSCEPTIBILITY TO EFFECTS OF THE EXPOSURE. CONTACT WITH SKIN MAY AGGRAVATE PRE-EXISTING DERMATITIS. ======================= First Aid Measures ======================= First Aid:INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION) . SKIN: FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD . EYES:FLUSH WITH W ATER FOR 20 MINUTES LIFTING UPPER AND LOWER LIDS OCCASIONALLY. CONSULT MD IF IRRITATION PERSISTS. ===================== Fire Fighting Measures ===================== Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE . Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:NONE KNOWN. ================== Accidental Release Measures ================== Spill Release Procedures:AVOID BREATHING DUSTS. SHOVEL INTO CLOSABLE CONTAINER FOR DISPOSAL. WEAR PROTECTIVE EQUIPMENT. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:DO NOT GET INTO EYES. AVOID BREATHING DUSTS. DO NOT SMOKE WHEN USING PRODUCT. KEEP CONTAINER TIGHTLY CLOSED WHEN NOT IN USE AND DURING TRANSPORT. Other Precautions:NONE SPECIFIED BY MANUFACTURER. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH/MSHA APPRVD RESP PROT EQUIP WHEN CONCENTRATION OF DUST EXCEEDS APPLICABLE EXPOS LIMIT. SELECTION & USE OF RESP PROT EQUIP SHOULD BE IN ACCORDANCE W/OSHA GEN INDUS STD 29CFR 1910.134-RESP PRO T & 1910.94-ABRASIVE BLASTING. Ventilation:PROVIDE LOCAL EXHAUST/GENERAL DILUTION VENT AS DETERMINED NECESSARY TO MAINTAIN CONC OF DUST BELOW APPLIC EXPOS LIMITS. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS. Other Protective Equipment:NONE REQUIRED. Work Hygienic Practices:USE GOOD PERSONAL HYGIENE. WASH THORO W/SOAP & WATER AFTER HNDLG & BEFORE EATING, DRINKING OR USING TOBACCO PRODUCTS. Supplemental Safety and Health EXPLAN OF CARCIN:CARCINOGENS, 1991:ANTICIPATED TO BE CARCINOGEN. ================== Physical/Chemical Properties ================== HCC:N1 Spec Gravity:3.1-3.8(H*2O=1) Solubility in Water:INSOLUBLE Appearance and Odor:POWDER-FREE FLOWING SAND, REDDISH-BROWN, ODORLESS ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG ACIDS, OXIDIZERS AND BASES. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:THERMAL DECOMPOSITION OF QUARTZ MAY RELEASE TOXIC AND/OR HAZARDOUS GASES. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.